Denso RC5 Specifiche Pagina 372

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 692
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 371
12-96
ST_ResetCompJLimit (Statement) [Ver.1.9 or later]
Function
Initializes the current limit under the compliance control (special compliance control
function statement) (exclusively designed for 6-axis robots).
Format
ST_ResetCompJLimit
Explanation
Initializes the current limit under the compliance control and set 0 to all axes.
Related Terms
ST_SetCompJLimit, ST_SetCompControl
Notes
(1) Execute this command in a TAKEARMed task that has obtained arm
semaphore. If this command is executed without arm semaphore obtained, Error
"21F7 Cannot take arm semaphore" will result.
Example
ST_ResetCompControl 'Disable the compliance control
ST_ResetCompJLimit 'Initialize the current limits
Vedere la pagina 371
1 2 ... 367 368 369 370 371 372 373 374 375 376 377 ... 691 692

Commenti su questo manuale

Nessun commento