Chapter 1 Sample Program
1-7
Program coding list "WAIT
SET" (Library)
'!TITLE “WAIT SET”
PROGRAM dioWaitAndSet(waitIndex%, ackIndex%)
Declares with argument. See p. 9-1.
RESET IO[ackIndex] Statement. See p. 13-7. 'Synchronization signal OFF
WAIT IO[waitIndex] = ON 'Waits for synchronization signal ON.
SET IO[ackIndex]
See p. 13-5. 'Synchronization signal ON
END
Program coding list "SET
WAIT" (Library)
'!TITLE “SET WAIT”
PROGRAM dioSetAndWait(ackIndex%, waitIndex%)
Declares with argument. See p. 9-1.
SET IO[ackIndex] See p. 13-5. 'Synchronization signal ON
WAIT IO[waitIndex] = ON 'Waits for synchronization signal ON.
RESET IO[ackIndex] Statement See p. 13-7. 'Synchronization signal OFF
END