Denso RC5 Specifiche Pagina 400

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 692
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 399
13-18
com_discom (Version 1.5 or later)
Function
Releases the RS-232C port from binary transmission. (Releases the COM port.)
If the Ethernet client port has been used, this command disables the Ethernet client
port to disconnect the Ethernet connection.
Format
com_discom #<portnumber>
Explanation
This command disables com_encom command to release the RS-232C
dedicated to binary transmission for other uses.
NOTE: Executing this command clears the RS-232C port once for preventing
data confusion between ASCII and binary data.
NOTE: If this command is executed during Ethernet communication, the
connection will be disconnected without waiting for completion of transmission.
The receiver may keep waiting for receiving non-transmitted data.
Example
'!TITLE "<Title>"
PROGRAM sample
.
.
.
com_discom #1 'Release port from binary transmission
.
.
.
end
Vedere la pagina 399
1 2 ... 395 396 397 398 399 400 401 402 403 404 405 ... 691 692

Commenti su questo manuale

Nessun commento